Features
- With the latest nuclear embedding technique to automatic control and data processing, to ensure reliability
- High performance liquid screen, to indicate parameters and measuring data
- Auto adjust negative high voltage and lamp current
- Auto transfer spectral bandwidth, 0.1nm, 0.2nm, 1.0nm, 2.0nmnm for option
- Auto control wavelength scanning, auto seeking, all band fast scanning and positioning in 30 seconds
- Auto zeroing could deduct zero drift of the influence to the data
- Auto energy adjustment
- Comprehensive gas leakage protection warning device
- The best flame height and atomizer position for option, to choose the best analysis condition
- Adjustable gas flow to select the best combustion supporting ratio of the element analysis
- Hydride generator for option
- The excellent quality of the optical system, optical system suspension design, the vibration and the environmental temperature changes can not affect the instrument performance
The basic parameters of AAS-2600 could be accordance with the basic parameters of the atomic absorption spectrophotometer in GB/T21187-2007 professional standard.
Performance Index
Optical system
- Wavelength: 190nm-900nm
- Monochromator: C-T, aberration
- Spectrum bandwidth: 0.2nm, 0.4nm, 1.0nm, 2.0nm for option
- Wavelength accuracy: ±0.25nm
- Wavelength repeatability: 015nm
- Baseline shift: ±0.004A/30min
- Detector: photomultiplier
Atomic system
- Sensitivity: concentration 3.0μg/ml, absorbance >0.300Abs
- (Cu) detection limit: 0.006μg/ml
- Burner: 100mm titanium metal, air premixed
- Precision: RSD≤1%
- Sprayer: high efficiency glass atomizer
- Atomizing chamber: corrosion resistant material
- Position adjustment: flame burner optimum height, front and rear position adjustable, complete the transfer between the flame and the hydride in one minute
- Safety: with many kinds of automatic protection, acetylene gas leakage alarm, closed system
Analytic method
- Measurement method: air-acetylene flame method, hydride generator atomic absorption method
- Concentration calculation: standard curve method (1-3 times curve), auto fitting, standard addition method
- Repetition survey frequency: 1-20times, calculate average value, ,display standard deviation and relative standard deviation
- Printing result: parameters print, data result print
Instrument Parameter
- Source: AC 220V/50HZ
- Power: 150VA
- Weight: 70Kg
- Volume: 1000mm (L)×350mm(W)×390mm(H)
- Operating temperature: 15℃~30℃
- Operating humidity: ≤75%
Standard Layout
- Main host
- Low noise oil free air compressor
- Accessories
- Installation and commissioning
- Wooden case packaging and transportation