ChemAuto2100
Advanced technology: Adopted CAS newly developed grating system, covering the wavelength range of 340nm to 900nm, higher accuracy and longer life.
Simple operation: No special work experience and technical training, staff two hours to learn can test sample on machine ,can be set up six test parameters in a continuous detection method to detect, easy to operate.
Quick Start: No need to waste time waiting for the system hydraulically balanced, after boot and click the software can detect.
Quick End: The system automatically performs the cleaning and monitoring cleaning results, no need for complex shutdown.
Accurate result: the use of temperature-controlled cuvette, completely eliminating the interference contrast color temperature meter, but also to eliminate the influence of different cuvette sample results, with good reproducibility and high accuracy. No manual factors interference, static testing, and the strapless over baseline drift, highly reproducible and accurate data.
Flexible settings: Automatic dilution from stock standard working standard solution, automatic sample dilution and excessive testing.
Low reagent consumption: each sample analysis requires only a few microliters of reagents.
Operating costs low: almost no consumables, instrument does not require frequent replacement hardware.
Operating software: Designed for chemists design, powerful, easy to operate and learn to use, but also easy researchers develop new methods.
Quality control: You can use five quality control, quality control results are automatically stored and can draw quality control charts.
CHEMAUTO series of Intermittent chemistry analyzer is the first automated chemistry analyzer, including intermittent flow cell type chemical analyzer, direct reading intermittent chemical analyzers, chemistry analyzers and other portable intermittent variety of products, all to meet the user a variety of demand.
CHEMAUTO series automatic intermittent chemical analyzer principle is classical wet chemical assay. Complete simulation of manual colorimetric operation, high degree of automation, rapid detection speed, and completely eliminate manual data accuracy problems were caused by human factors operating.
CHEMAUTO degree of automation is much higher than continuous flow analyzer (CFA) and flow injection analysis (FIA). Analysis of the whole process is not flowing liquid, no bubbles, no need to wait for steady baseline, baseline drift and no more troubled with too static colorimetric detection, more accurate analysis results.
CHEMAUTO computer controls the entire reaction process, sensors and monitors for reagents, samples, quality control, chemical reactions and cleaning steps and monitor the entire process anomalies alarm, truly fully automated testing.
CHEMAUTO integration advantages of similar foreign products and bold breakthrough, using a grating spectroscopic techniques, wider range of applications.
CHEMAUTO Applications
Surface water, drinking water, wastewater routine testing parameters
Ammonia |
Hardness |
Sulfate |
Chloride |
Kjeldahl nitrogen |
Alkalinity, |
calcium , |
silicate |
sulphate |
Kjeldahl phosphorus |
Chroma |
Chlorine |
Chromium (IV) |
Phenol |
TN |
Nitrite |
Nitrate |
Total dissolved iron |
Cyanide |
Soil and plant extracts routine testing parameters
Ammonia |
Phosphate |
Calcium |
Nitrite |
Chloride |
Boron |
Nitrate |
Total Kjeldahl nitrogen |
Total Kjeldahl phosphorus |
Parameters
ChemAuto 1100 | ChemAuto 1200 | ChemAuto 2100 | |
Detection method | Flow Cell Formula | Flow Cell Formula | Direct reading |
Detection method | Endpoint detection, differential detection, timing detection, motion detection | Endpoint detection, differential detection, timing detection, motion detection | Endpoint detection, differential detection, timing detection, motion detection |
Sample tray | 60, can be placed on the sample, blank, standard solution or control | 60, can be placed on the sample, blank, standard solution or control | 110, can be placed on the sample, blank, standard solution or control |
Reagent tray | 27, Peltier cooling | 27, Peltier cooling | 36, Peltier cooling |
dilution | 1000ml syringes, precision 1ml, automatic zero setting, accuracy ±0.5% (5ml-1000ml) | 1000ml syringes, precision 1ml, automatic zero Setting accuracy ±0.5% (5ml-1000ml) | 1000ml syringes, precision 1ml, automatic zero setting, accuracy ±0.5% (5ml-1000ml) |
Reaction disk | 96 reaction cell temperature can be controlled, precision ±0.10C | 96 reaction cell temperature can be controlled, precision ±0.10C | 120 reaction tank, the temperature can be controlled, precision ±0.10C |
Splitting system | 340-900nm grating system | 340-900nm grating system | 9 + 1 blank filters |
Colorimeter | 10mm standard cuvette volume 35ml, cuvette temperature can be controlled, precision ±0.10C | 10mm standard cuvette volume 35ml, cuvette temperature can be controlled, precision ±0.10C | 10mm optical plastic cuvettes, volume 350ml, cuvette temperature can be controlled, precision ±0.10C |
Wash | Automatic cleaning sampling needle | Automatic cleaning sampling needle | Sampling needle inside and outside cleaning, Automatic Clearing |
Light source | Halogen | Halogen | Halogen |
standard solution | Up to 10 standard solutions, standard curve can be stored and the next can be called linear regression or polynomial regression | Up to 10 standard solutions, standard curve can be stored and the next can be called linear regression or polynomial regression | Up to 14 standard solutions, standard curve can be stored and the next can be called linear regression or polynomial regression |
Test Methods | One way you can set multiple parameters continuously detected | One way you can set multiple parameters continuously detected | One way you can set multiple parameters continuously detected |
Detection speed | Up to 150 analyzes / hour (depending on the method) | Up to 200 analyzes / hour (depending on the method) | Up to 300 analyzes / hour (depending on the method) |
Liquid level detection | no | no | Have |
Automatic cleaning | Have | Have | Automatic cleaning section 7 |
data transmission | USB Interface | USB Interface | USB Interface |
Reagent tray system cooling | Independent power switch, turn off the host still work after cooling | Independent power switch, turn off the host still work after cooling | Independent power switch, turn off the host still work after cooling |
Cleaning and Waste Liquid bottle | Have | Have | Have |
Ambient temperature | 5 ° C - 35 ° C | 5 ° C - 35 ° C | 5 ° C - 35 ° C |
Relative humidity | 20% -80% | 20% -80% | 20% -80% |
power supply | 220V | 220V | 220V |