Overview
PT-D93-1002C automatic closed cup flash point tester (Pensky Martins method) conforms to the ASTM D93 standard test methods for flash point by Pensky-Martens Closed Cup Tester, this tester covers the determination of the flash point of petroleum products in the temperature range from 40 to 360°C by an automated Pensky-Martens closed-cup apparatus, and the determination of the flash point of biodiesel in the temperature range of 60 to 190°C.
Features
- Highly automatic design, the instrument automatically competes control, sweeping ignition, flash examination, alarming, result calculation and etc. it can complete all the experiment procedures with nobody watches.
- The apparatus configures high precision needle-type valve to control gas resource, can precisely ensure testing flame ball as standard ASTM D93 required.
- All the gas source pipes are made of stainless steel, which made it safe and reliable.
- The tester conforms to the A and B procedures of the standard ASTM D93 requirement to truly realize two experiential methods tested in one instrument and a quick search method allows for determination of flash point for unknown samples.
- There is a lighting ignition plug equipped on the flame ball, which ensures the fireball burns all along during the testing process, safe and reliable.
- The apparatus equips with highly efficient fan cooling system, user can accelerate to start the next test in short time by launching cooling system .that improves efficiency.
- Convenient to use, friendly big LCD touched screen operation and press one button rapid experiment function.
- The tester equips with Multiple indicating lights, which makes users understand all the working condition and analyze stoppage perfectly.
- Decent and elegant appearance, testing table is made of stainless steel, easy to clean and simply strong.
- The apparatus is equipped with thermo printer which can print testing result directly. That’s convenient to record and got Large memory space to store experiential data permanently.
- The apparatus will automatically correct the actual atmospheric pressure to standard pressure(101.3kPa).
- A differential Pt-100 RTD probe is designed to duplicate the response time of a mercury-in-glass thermometers as per ASTM D93 and E1
- User can interface the system with an external PC for operation and update the method.
Technical parameter
1. Rated voltage: AC220V±10% 50HZ
2. Power: 700W
3. Ignition way: fuel gas ignition
4. Screen: 4 wires resistance touched LCD
5. Cooling method: double enforcing fan cooling system
6. Printing way: thermo sensitive printer
7. Ambient requirements: temperature 15~30°C, humidity: ≤85%