Incubator

CO2 incubator, professional LFZ-COI Series

professional LFZ-COI Series

CO2 incubator, professional LFZ-COI Series

More details

More info

Touch screen Controllers (RHP & RWP)

  1. 7-inch resistive touch screen control which is flexible operation, more user-friendly
  2. Can display real-time operation curve, with curves summary function, can directly view the changes of temperature, dioxide carbon and humidity; also can display abnormal alarm and open information.
  3. 72 hours working records search function
  4. Touch screen lock feature to avoid human touch and change the experimental data or downtime.

 Imported infrared (IR) sensor

  1. Quickly monitored carbon dioxide gas and not affected by ambient temperature and humidity fluctuations etc., suitable for frequency door opening operation.

Sterilization system

  1. 90 °C high temperature wet/heat sterilization(RHP), can sterilize internal chamber including a temperature sensor, carbon dioxide concentration sensor and fan, eliminate microbial contamination of bacteria, fungi, mycoplasma and other microorganisms for cell culture caused, provide a secure environment for the growth.
  2. Ultraviolet sterilization system(RWP), UV germicidal lamp at the top of the rear side of the box, inside the box regularly to sterilize effectively kill cabinets and humidifying the circulating air or water dish water tray at the bottom of the slope of the vapor floating bacteria, thereby effectively preventing contamination during cell culture .

◆Temperature control and monitoring system

  1. Box incubator temperature control system, Pt100 temperature probes to ensure accurate temperature inside. Can be set inside the actual temperature and the temperature difference between the real-time adjustment of the heating power, the actual temperature cabinets ensure precise. The user can switch the door after sampling and loft, 3 minutes recovery test temperature.
  2. Door temperature heating system, has a heating function outside the door, the door to follow me warm and slightly higher than the temperature tank temperature, which can effectively prevent water condensation glass door, easy to observe the experiment, and the glass door to avoid the generation of condensate brought the possibility of microbial contamination.
  3. Environmental temperature monitoring system, independent of the ambient temperature sensor, it can be based on experiments in ambient temperature changes automatically adjust the CO2 incubator heating system to prevent the inside temperature overshoot occurs.
  4. Over-temperature protection system, independent of the standby temperature control system CO2 incubator temperature control box outside the system, when the incubator temperature control system fails causing runaway temperature, the working temperature of the indoor temperature controller setpoint limit, over-temperature protection system will automatically cut off the heating, and sound and light alarm.
  5. Power failure alarm function, the power situation in real-time detection of the incubator, when the power failure and loss of power occurs, immediately audible and visual alarm signal to training keep user safe and reliable operation without accidents.

 HEPA high efficiency filter (optional)

  1. Can effectively filter out bacteria in the outside air and dust particles, eliminate and prevent cross contamination between chamber and outside air. So that incubator working in sterile condition.
  2. HEPA high efficiency filter ensure air recover to class 100 purify level within 5 minutes.

Security features

  1. Independent limit temperature alarm system that can audible alarm prompts the operator to ensure the safe operation of experiment is not an accident;
  2. Power supply fault alarm systems, to sound and light alarm operator;
  3. Over temperature alarm
  4. Chamber/door sensor fault alarm
  5. CO2 over concentration alarm;
  6. Long time to open the door alarm
  7. Disinfection work status and other safety reminders.

 microbial efficiency filter, door temperature heating systems, automatic fan speed control

  1. CO2 air intake with efficient microbial filter for diameter of 0.3 μ m or greater particle, filtration efficiency up to 99.99%, effective filtration of bacteria in the CO2 gas and dust particles.
  2. Heated internal glass doors to avoid condensation of water to prevent the possibility of microbial contamination.
  3. Fan speed be controlled depends on the demand automatically.

Specifications:


Model

LFZ-COI-80CRH
LFZ-COI-80RHP

LFZ-COI-150CRH
LFZ-COI-150RHP

LFZ-COI-240CRH
LFZ-COI-240RHP

LFZ-COI-60RWP

LFZ-COI-170RWP

LFZ-COI-240RWP

Power Supply

AC220V/50Hz

Input power

500W

750W
700W

1000W

500W

700W

1000W

Heating type

Air-jacket

Water-jacket

Controller

LED
LCD touch

LCD touch

Temp. Range

RT+5~50°C

Ambient temp.

+5~30°C

Temp. Fluctuation

±0 1°C

CO2 range

0~20%

CO2 accuracy

±0.1% (Infrared sensor)

CO2 recovery time

(door opening 30 seconds recover to 5%)≤3 min

Temp. Recovery time

(door opening 30 seconds recover to 37°C)≤ 8 min

Relation humidity

Nature evaporation>95%(Relate humidity display is optional)

Capacity

80L

155L

233L

60L

170L

240L

Inner size (mm)W×D×H

400×450×500

480×530×610

600×630×670

380×290×550

530×460×7200

600×520×780

Dimensions (mm)W×D×H

590×690×790

670×770×880

790×840×940

534×530×790

684×700×960

754×760×1020

Shelf

2 pcs

3 pcs

2 pcs

3 pcs

UV sterilizer

Ultraviolet lamp sterilization
90°C high temperature & humidity (UV disinfection optional)

UV disinfection

 Optional items


RS485/232 & software

carbon dioxide pressure reducing valve

Humidity display system

Wireless alarm system(SMS)

HEPA filter system

Test hole

3Q Verification and calibration services

 

28 other products you may be interested: