PA-1156LW
To obtain accurate test results for particle size testing, the sampling of the test sample must be representative, and the test sample must be completely dispersed into individual particles before measurement. PA-1156LW laser particle size analyzer uses a unique device to achieve instantaneous dispersion and instantaneous measurement, thereby ensuring good repeatability and stability. The instrument is easy to operate and has a fast test speed. Within 1 minute of each sample, it can be continuously and automatically tested to verify the authenticity of the test results. It is automatically recorded and saved by the computer for easy viewing and printing.
Sample cell
Application:
Scientific research institutions, electronic materials, chemicals, pesticides, pigments, pharmaceuticals, titanium dioxide, ceramics, building materials, coal water slurry, cosmetics, abrasives, coatings, food, calcium carbonate, talc, kaolin, papermaking, alumina, rare earths, catalysts , Particle size distribution test of solid powders and emulsions in various industries such as foaming agents, refractory materials, cement, pearlescent pigments, graphite, etc.
Features:
Main parameters:
Model | PA-1156LW |
Measuring range | 0.1µm~1000µm |
Repeatability error | ≤1% (deviation of national standard D50) |
Accuracy error | ≤1% (deviation of national standard D50) |
Quality requirements | Acceptance with standard powder according to Q / 70920531-0.1-2016 |
Sample pool | Volume: 500mL all stainless steel 304 |
measurement accuracy | 50% volume cumulative particle size value repeatability <1% (national standard material) |
Signal light source | Imported semiconductor laser, wavelength 635nm, 3mw, life time> 25000h Laser product grade: first grade |
Light path design | Parallel light path design, stable and reliable, in line with ISO13320, ISO13321 and other international standard principles. |
Test range | Tested in 3 levels; ultra-fine powder, fine powder, coarse powder. |
Detector | 98-level multiple detector |
Laser life | More than 70,000 hours |
Injection method | Put the powder into the sample cell according to the computer prompts, and the water will be fully fed, ultrasonic dispersion, stirring, and peristaltic pump circulation. |
Light path system | Inverted Fourier Optical System |
Signal light source | Imported semiconductor laser |
Decentralized | Built-in 60w ultrasonic disperser, ultrasonic time, mechanical stirring (adjustable 100-600 rpm), and peristaltic cycle time can be set as required. |
Dispersion medium | Tap water (can also be distilled water, ethanol, etc.) |
Sample quantity | Mg ~ g (related to the specific gravity, particle size and refractive index of the sample) |
Sample detection cell | 60mm × 60mm high-quality optical glass |
data processing | Mie theory and proprietary analysis software. |
Dimensions | Length 740 × width 340 × height 530 (mm) Weight: 65kg |
Working power, environment | AC220V ±22V 50Hz ±0.5Hz Environmental requirements: temperature: 5 °C ~ 35 °C; humidity: <85%; |
Main configuration | 1. Main machine (contains optical system, sample dispersion system, circulation system) 1 set |