PA-1178LD
In the field of powder particle size testing, magnetic materials, lithium carbonate, medicinal powder, cement, chemical, and other powders that are not suitable for water (wet method) testing. To obtain accurate test results, dry method laser particle size meters are generally used for measurement. PA-1178LD dry-type laser particle size analyzer uses a unique device to realize instantaneous dispersion and instantaneous measurement, thereby ensuring the repeatability and stability of the instrument. This instrument has fast test speed, fully automatic operation, and stable results. It is the first choice for testing dry powder particle size distribution in various industries.
Application
Magnetic materials, medicinal powder, cement, powder coatings, chemicals, food, pesticides, electronics, papermaking, metallurgy, ceramics, building materials, abrasives, calcium carbonate, talc, kaolin, alumina, rare earth, catalysts, blowing agents, fillers, graphite , Pigment and other industries of solid powder particle size testing.
Instrument Features
Instrument main parameters
Model | PA-1178LD |
Test principle | Full range Mie scattering theory |
Measuring range | 0.01µm~3000µm |
measurement accuracy | ≤3%(national standard material D50) |
measure time | Test a sample within 1 minute |
Sample volume | 2g~10g |
Light path design | Parallel beam path, Fourier lens, automatic centering |
Software operating environment | Windows |
Operation method | Fully automatic operation. After placing the powder in the sample tank, you only need to click the mouse, and the entire testing process is fully automatic under the control of the computer. |
Signal light source | Imported semiconductor laser |
Laser life | More than 70,000 hours |
Detector | 128-level multi-element detector is a three-dimensional array of front, back, and side (patented) with a maximum detection angle of 165 degrees. |
Decentralized | The dry turbulent dispersion method adopts a unique sampling device, which is coordinated by the air compressor and the vacuum cleaner, and the dispersion time is short. |
Dispersion medium | Compressed air / Nitrogen must be used if the powder is to be burned after contact with air |
Dispersion time | <5 seconds / times |
Dispersion pressure | 0.1—0.8Mpa adjustable |
Result output format | The results show particle size distribution tables and graphs. And D10, D50, D75, D84, D90, D97, average particle size and specific surface area and other data. |
Working power | AC220V ± 10% 50Hz |
PA-1178LD dry laser particle size analyzer configuration
No | Description | Unit | Quantity | Remark |
1 | PA-1178LD Dry Laser Particle Size Analyzer | SET | 1 |
|
2 | Instrument auxiliary machine | SET | 1 |
|
3 | Oil-free silent air compressor | SET | 1 |
|
4 | Dedicated particle size analysis software | SET | 1 |
|
5 | Instrument operating instructions | PC | 1 |
|
factory inspection report | PC | 1 |
| |
test certificate | PC | 1 |
| |
Certificate of conformity | PC | 1 |
| |
6 | Power strip | Group | 1 |
|
power cable | PC | 2 |
| |
Instrument-specific communication line | PC | 1 |
| |
oxygen tube | PC | 1 |
| |
Dust extraction pipe | PC | 1 |
| |
screwdriver | PC | 1 |
| |
Allen wrench | PC | 1 |
| |
Sample (with test report) | Butch | 1 |
| |
Apron | PC | 10 | spare | |
Sample slot | Group | 2 |
| |
Glass cover (large lens) | PC | 1 | spare | |
Serial cable | PC | 1 |
| |
Ear wash ball | PC | 1 |
| |
brush | PC | 1 |
| |
Sampling spoon | PC | 1 |
| |