PA-1177ALW
PA-1177ALW full-automatic laser particle size analyzer is based on international standard principles such as ISO13320, full-range Mie scattering theory and proprietary technology analysis and calculation. The instrument's built-in camera system can visually test the particle morphology of samples in real time. Fully sealed metal casing with good electromagnetic shielding and anti-interference performance. The optoelectronics, sample cell, circulation system, etc. are set inside the instrument to make the sample flow in the pipeline for a short time, avoiding delamination and re-layering after the sample is dispersed. Reunion, a veritable mechatronics new generation particle size testing instrument. High degree of intelligence, fast test speed and good stability. It can be completed within 2 minutes for each sample. The result is automatically recorded and saved by the computer, and it is convenient to view and print.
Application area
Scientific research institutions, electronic materials, powder coatings, papermaking, chemicals, ceramics, building materials, manganese carbonate, pesticides, pigments, medicine, coal water slurry, cosmetics, abrasives, food, calcium carbonate, talc, kaolin, alumina, rare earth, Catalyst, foaming agent, refractory, cement, graphite, marine sediment and other industries of solid powder, emulsion particle size distribution test.
Instrument advantages
Report specifications:
Software operation interface can choose Chinese or English as required. Multiple report forms: free distribution, normal distribution, RR Distribution, etc. Content includes cumulative particle size distribution data and curves, interval particle size distribution data and histograms, typical particle size values such as D3, D10, D25, D50, D75, D84, D90, D97, volume average particle size and area average particle size and specific surface area and other data.
Technical Parameters
Model | PA-1177ALW |
Measuring range | 0.01µm ~ 3000µm |
Repeatability error | ≤1% (deviation of national standard D50) |
Accuracy error | ≤1% (deviation of national standard D50) |
Light path system | Inverted Fourier Optical System |
Signal light source | Imported semiconductor laser |
Working power | AC220V ± 22V 50Hz ± 0.5Hz |
Sample detection cell | 60mm × 60mm high-quality optical glass |
Sample dispersion cell | Volume 500mL, material: 304 all stainless steel |
Decentralized | 60w ultrasonic disperser |
detector | 128-level multiple detector |
Laser life | More than 70,000 hours |
Environmental requirements | Temperature: 5 °C ~ 35 °C; Humidity: <85%; |