Preparator & Dispenser

Automatic Medium Preparation Instrument

HMP-12&HMP-30

More info

Product Description:
High-quality media is the core of all kinds of biological culture in today's laboratories. Many follow-up work depends directly on the quality of the medium. An efficient preparation process is also important, which not only reduces laboratory labor costs, but also frees researchers from tedious and repetitive tasks. The HMP preparator Automated Media Reader is flexible – ready to allow you to quickly sterilize and prepare high quality media. This minimizes the space required to store the finished petri dish, eliminates the management of the petri dish storage, and ensures high quality media uniformity. It can quickly and gently sterilize the medium and accurately monitor and control the time, temperature, pressure and other parameters in the sterilization process, so as to ensure that all sterilized products have the same high quality, its intuitive graphical interface and The programming function makes it easy for everyone to operate the instrument.

HMP preparator can be quickly prepared for sterilization, placed in a sterilizer, and filled with water in a “water jacket system” (sleeve water between the sterilizer and the sterilizer cavity for efficient heat transfer), added to the medium Raw materials, ready to start the sterilization process. The medium can be suspended and dissolved directly in HMP preparator. Strong magnetic stirring ensures uniformity of mixing in the inner chamber and prevents condensation. The medium can be pre-dissolved in WATER BATH mode prior to sterilization. At the same time, an intuitive graphical interface makes it easy to operate without specially trained personnel. Users can customize multiple sterilization procedures, such as sterilization temperature, time, and dispensing temperature.

Operating mode:
It has 2 main working modes and 2 additional modes to choose from, and the parameters can be set by yourself.

  • Standard mode: Prepare standard medium, or high sensitivity medium. Sterilization temperature/time and dispensing time can be set.          
  • Chocolate Agar Mode: A special 2-step preparation procedure for preparing complex media. After one sterilization, nutrients such as blood may be added through the feeding port, and then the temperature is raised twice.
  • Water bath mode: Dissolve the medium at 30 – 80 °C before formal sterilization. Glassware can be placed in the sterilizer and the liquid in the glassware can be heated in a water bath.
  • Sterilization mode: When the sterilization mode is enabled, it can be used as a common table sterilizer to sterilize a small number of test tubes, flasks and other glassware.

Medium sterilization
HMP preparator ensures fast and gentle preparation of standard and highly sensitive media. The efficient heating and cooling system plus uniform agitation minimizes the thermal stress on the medium and ensures the nutrient of the medium.

Highly safe operation
Before the start of sterilization, there will be a program to automatically check the air tightness of the whole system, for example, whether the sealing ring of the lid is intact, which can prevent the medium from suddenly leaking during the sterilization process and cause pressure relief.
The HMP preparator is equipped with 4 independent temperature/pressure detectors to ensure a high level of safety for the user and the working environment. It is equipped with an independent over-voltage safety protection device to automatically relieve pressure when the electronic detection system fails.

Rapid heating
Efficient heating elements ensure rapid heating of the medium. This can reduce thermal stress and ensure the nutrient of the medium. The temperature and pressure controlled exhaust system ensures vapor saturation in the chamber, ensuring complete sterilization of the medium.

Reliable sterilization
Equipped with a powerful magnetic stirrer, the mixing speed and direction can be adjusted to ensure that the medium with different consistency can be stirred evenly. The Pt-1000 temperature probe and various operating parameters controlled by the microprocessor ensure complete and reliable sterilization results.

Rapid cooling
The rapid cooling system uses an efficient plate heat exchanger. The cooling water system and the sterilization chamber are internally isolated, which prevents the cooling water from contaminating the medium. The built-in pressure maintenance system prevents the boiling of the medium due to pressure drop during the cooling process, resulting in a fast and gentle cooling.

Simple dispensing
The large auxiliary material addition port can easily and safely add various additives such as antibiotics, blood, growth factors and the like. The automatic simultaneous sterilization process of the dispensing port eliminates the risk of media contamination during the dispensing process. Special cavity design and dispensing system minimizes “residual” and maximizes lab costs.
HMP preparator can be quickly and easily connected to a fully automated media plate dispenser or a manual dispensing peristaltic pump. It can also be applied to containers of various other shapes, such as squares, flasks or flasks.

Sterilization data record
HMP preparator provides tools that are needed for data logging, including sterilization parameters, work status, etc., to support long-term data storage.

Cleaning and maintenance
The built-in cleaning program automatically sterilizes chambers, pipes and valves. High temperature interlayer water can be discharged at the end of the process to dissolve and eliminate residual media. This allows all pipes and components in the entire machine to be sterilized, providing a good environment for the next use.

Technical parameters:


Model

HMP-12

HMP-30

Capacity

12L, cavity 17L

30L, cavity 43.7L

Cavity size

296mmx250mm

296mmX650mm

Bucket size

260mmx222mm

222mmX 622mm

Sterilization temperature

70-122 ° C

70-122 ° C

Packing temperature

25-80 ° C

25-80 ° C

Water bath temperature

30-80 ° C

30-80 ° C

Maximum working pressure

2.5bar

2.5bar

Design pressure

4bar

4bar

Cavity sterilized water

deionized pure water
can automatically enter water (pressure is not less than 1bar)
high and low water level alarm

Cooling water interface

2 points inner wire diameter 12 pagoda joint

Circulating water

pressure is not less than 1bar tap water

Drainage interface

2 points inner wire diameter 12 pagoda joint

Temperature accuracy

0.1 ° C

0.1 ° C

Temperature offset

1 ° C

1 ° C

Time setting accuracy

1 minute

1 minute

Sterilization pot material

1.4301/1.4305

1.4301/1.4305

Dispense port

2 pcs, can adapt to a variety of sub-assembly requirements
one of which can also be used for aseptic addition of materials

Packing hose

inner diameter 6mm, thickness 2mm

inner diameter 6mm, thickness 2mm

Material addition port

diameter 32mm

diameter 32mm

Stirring

powerful magnetic stirring
high speed 240rpm, low speed 120rpm adjustable

Heating power

3.6KW

10KW

Power requirements

220-240V, 50/60Hz, 16A

3x380-420V, 50/60Hz, 16A

Dimensions (mm)

480*555*635 (H*L*D)

965*555*655 (H*L*D)

Net weight

50kg

70kg