Product Features:
1) Exclusive use of the excitation light source drift correction technique, by adding detector for detecting light signal on the same line of the excitation light source the position, by detecting drift excitation light source, the measurement error correction caused by the drift of the light source, completely solve the instrument problems long-term stability of the measurement.
2) Application of industry-leading fifth-generation sequential injection - intermittent flow method for the current atomic fluorescence peristaltic pump injector and injection pump injection in two ways, give full play to their respective advantages, both high reliability (simple structure, low failure rate ), rapid measurement speed, precision injection, extend the service life of the injection pump, cleaning time is short and so on. At the same time the exclusive use of the peristaltic pump injector and injection pump injection automatic switching function, when you need to automatically configure the standard curve or the sample concentrations exceeding encounter, automatically switches to the injection pump injection of standard or sample is diluted again after switching to a peristaltic pump injection method continue to measure, which greatly improves the injection pump life, reduce user costs.
3) Have an exclusive intermittent injection and continuous injection are two ways to inject way, when your sample is large and require precise measurement, the application software continuous injection method can play a huge advantage, by increasing sampling time to increase the injection volume to eliminate interference during the measurement, to meet the high requirements of accuracy and stability of the samples measured.
4) The exclusive use eliminate of the inter-channel interference, effectively remove the current channel signal  whichcoupling capacitor storage, eliminating the impact on the next channel signals, to ensure that each data is accurate and reliable.
5) Unique sample blank cleaning monitoring function, full control the sample measurement process, compares reactions between before sampling and after cleaning ,,automatically determine whether the flow path clean. Reduce the difficulty of users.
6) Exclusive use of the new syringe cleaning device, cleaning the outer wall of each needle before the measurement, to avoid contamination of carriers to ensure the accuracy of the low concentration of the sample.
7) Modular architecture design, CAN bus modular circuit design and modular mechanical design, classify the instrument according to the functions into a plurality of independent modules ,enhance reusability and instrument interchangeability between modules, save maintenance costs, reduce system complexity, with system scalability.  
Technical Parameters:
The detection limit DL:
    As, Se, Pb, Bi, Sb, Te, Sn <0.01μg / L
    Hg, Cd <0.001μg / L
    Ge <0.05μg / L
    Zn <1.0μg / L
    Au <3.0μg / L
The relative standard deviation RSD <0.8%
Linear range: more than three orders of magnitude

Features:
1. For twelve kinds of element trace analysis in samples, such as arsenic, mercury, selenium, lead, germanium, tin, antimony, bismuth, cadmium, tellurium, zinc, gold.
2. Triple channels, three elements simultaneous measurement
3. The modular design has independent intellectual property rights.
4. Own intellectual property rights of built-in intermittent flow sampling device which the second generation import syringe pumps and peristaltic pump in combination usage
5. The solenoid valve has a proprietary application: abandon the traditional one-way valve, multi-channel valve and pinch valve.
6. With independent intellectual property rights of dual detector and double channel simultaneous detection function.
7. Exclusive with intermittent injection and continuous injection two ways Injection mode automatic switching function.
8. Exclusive with peristaltic pump injector and injection pump injection automatic switching function.
9.Have independent intellectual property rights to eliminate inter-channel interference.
10. With independent intellectual property rights of the new syringe cleaning device.
11. Using ten rollers, six channels, each channel can be adjusted independently of dedicated peristaltic pump.
12. The constant current pulse power supply.
13.. Can equip trap using hydride generation atomic fluorescence measurement of harmful elements in the exhaust.
14. The high-efficiency gas-liquid separator.
15. The use of new closed second level gas-liquid separator.
16. The use of special air-core coding cathode lamps, automatic identification elements.
17. The unique design of cryogenic shield quartz furnace atomizer.
18. Advanced membrane separation type gas-liquid isolator.
19. The pneumatic system uses an array formula: automatic and accurate control of gas flow.
20. One key operating functions: to achieve fully automated operation, and equip with 145bit auto sampler and 205 bit auto sampler optional.
21. Intelligent automatic functions online optimization analysis conditions: automatic negative high voltage settings, automatic gas path settings dynamically adjust the air-core line cathode lamps, dynamic monitoring, POST, automatic diagnosis, automatic fault alarm functions.
22. Unique blank cleaning monitoring.
23. The software enables measurement data quickly import to office, network resources sharing.
24. Apply for all software workstation under Windows operating systems, Powerful online expert help system..
25. USB interface and RS232 interface can be chose arbitrarily.
26.Having argon and hydrogen flame and elemental lamp operation state observation window.
27.Can be upgraded to liquid chromatography atomic fluorescence spectrometer, for analysis of elemental speciation and valence.

 